In the world of flow measurement, where precision and reliability are crucial, choosing the right flow meter can make all the difference. Traditional Insertion Mag Meters provide cost-effective solutions but fall short in capturing the full flow profile, leading to reduced accuracy in certain conditions. The FPI Insertion Mag Meter addresses these limitations by delivering the next level of precision with full-profile measurement and seamless installation. In this article, we’ll explore the benefits and working principles of both types of meters, focusing on the FPI Mag Meter as a featured product for high-demand applications.
Key Takeaway:
- Precision & Reliability: Both Insertion Mag Meters and FPI Insertion Mag Meters offer electromagnetic solutions for highly accurate flow measurement.
- Traditional Insertion Mag Meters: Provide easy installation and cost-efficiency, but measure only part of the flow profile, resulting in reduced accuracy in non-ideal conditions.
- FPI Insertion Mag Meters: Capture the full flow profile across the pipe diameter, delivering ±0.5% accuracy, comparable to full-bore meters.
- Hot Tap Installation: FPI meters can be installed or removed without shutting down the pipeline, minimizing downtime in large-diameter applications.
- Ideal for Tight Spaces: FPI meters offer flexibility in installations where space is limited, ensuring performance in industrial and municipal applications.
- Low Maintenance: No moving parts, making the FPI meter durable and easy to maintain over the long term.
- Balanced Solution: FPI meters combine the accuracy of full-bore meters with the ease of installation and cost benefits of insertion meters, making them an optimal choice for large-scale operations.
What is an Insertion Mag Meter
Insertion Mag Meters are specialized flow measurement devices that utilize electromagnetic principles to measure the flow of conductive fluids within pipes. One example of advanced insertion mag meters is the Full Profile Insertion mag meter (FPI) here:

The key advantages of insertion mag meters, in general, include easy installation without the need for shutting down the pipeline, making them ideal for large-diameter pipes and retrofits. They have no moving parts, which ensures low maintenance and long-term reliability.
These meters provide accurate, real-time flow data even in challenging environments, such as wastewater treatment and industrial processes. Their ability to be installed under live conditions and their cost-effectiveness make them a preferred choice in many industries.
Working Principle of Insertion Mag Flow Meter
An Insertion Mag Flow Meter functions based on Faraday’s Law of Electromagnetic Induction, which states that when a conductive fluid moves through a magnetic field, it generates an electrical signal proportional to its velocity within that field. This principle is key to how the meter measures fluid flow.
1. Fluid Conductivity:
- For accurate operation, the fluid being measured must be electrically conductive. A minimum conductivity of 5 µS/cm is typically required, though some advanced meters can handle slightly lower levels. Insufficient conductivity will result in the meter not producing a readable voltage, leading to inaccurate or no flow measurements.
2. Faraday’s Law Application:
- Faraday’s Law explains that the voltage (E) induced in the fluid is directly proportional to its velocity (V), the magnetic field strength (B), and the distance between the electrodes (D). The formula is:
- E ∝ V × B × D
- E = Voltage generated in the conductor (fluid)
- V = Velocity of the fluid
- B = Magnetic field strength
- D = Distance between electrodes
- E ∝ V × B × D
- As the fluid flows through the magnetic field generated by the coils, the conductive particles within the fluid induce a voltage. This voltage is then detected by the electrodes positioned within the insertion probe, and it is directly proportional to the flow velocity. The meter’s electronics convert this voltage into a flow rate, which is displayed or transmitted for monitoring.

3. Magnetic Field Considerations:
- The accuracy of the flow meter relies on the strength and uniformity of the magnetic field. Various factors can influence this, including:
- Pipe Material: Metal pipes can distort the magnetic field, making proper grounding and insulation necessary to maintain accuracy.
- Electromagnetic Interference: Nearby electrical equipment can cause interference, introducing noise that affects the measurement. Ensuring proper installation and grounding can mitigate these effects.
How an Insertion Electromagnetic Flow Meter Works
- Magnetic Field Generation:
- The insertion mag meter contains coils that generate a magnetic field across the section of the pipe where it is installed. This field is perpendicular to the fluid flow.
- Electrode Interaction:
- Electrodes, placed within the insertion probe and in direct contact with the fluid, detect the voltage induced as the fluid moves through the magnetic field. This voltage is proportional to the fluid’s velocity.
- Signal Conversion:
- The induced voltage is transmitted to the flow meter’s electronics, where it is processed and converted into a flow rate measurement. The flow rate can then be displayed locally or transmitted to a control system for further use.
- Calibration and Output:
- The meter’s electronics use calibration data specific to the fluid and pipe configuration to ensure accurate measurements. The output, typically in the form of a digital signal or a 4-20 mA analog signal, integrates seamlessly with SCADA systems or other monitoring equipment.
Calibration, Maintenance & Installation:
- Calibration: Regular calibration is essential to maintain accuracy, especially in critical applications. Calibration can be done in-situ, minimizing downtime.
- Maintenance: Periodic cleaning of electrodes is necessary to prevent buildup that can affect accuracy, especially in fluids with high levels of particulates.
- Installation Environment: Proper installation, including grounding and considering the surrounding environment, is crucial to avoid errors due to electromagnetic interference or pipe material effects.
Related post: How Insertion Mag Meters Work
What is the FPI Magnetic Flow Meter?
FPI is known as a Full-Profile Insertion Magnetic Flow Meter. It performs just like a full-bore mag meter, but its unique form gives it an advantage in a wide variety of applications.
The FPI Mag meter represents the next generation of magnetic flow meter technology development. It employs a unique and ground-breaking configuration whereby the coils and electrodes are assembled in a tube that inserts into a pipe perpendicular to the full profile of the flow stream.
Featured Product: McCrometer’ Full Profile Insertion Mag Meter
Designed to be installed (or removed and serviced) without shutting down or cutting the line and without heavy equipment, the FPI Mag™ Flow Meter provides an exceptionally low installed and life-cycle cost.
Hot tap insertion allows the flow meter to be installed without interrupting service, de-watering lines, cutting pipe or welding flanges.
The flow element can be removed from the line without shutting down water flow, cleaned, inspected, calibrated or verified with a simple process and then replaced without an expensive line shutdown and restart sequence.

The Only Hot Tap Full Profile Insertion Mag Meter
The FPI Electromagnetic Flow Meter is the premier choice for capital projects, maintenance tasks, retrofits, and new installations, even in locations that have never been metered before. This cutting-edge meter combines unmatched accuracy with effortless installation, thanks to its hot tap capability, which allows for installation and maintenance without shutting down pipelines. This feature alone can save significant time and costs, particularly in large-diameter pipes.
McCrometer’s FPI Mag leverages an advanced multi-electrode design, ensuring precise measurements that rival full-bore mag meters, making it ideal for both municipal water systems and demanding industrial environments. Its durable construction, featuring no moving parts, ensures long-term reliability and minimal maintenance, even in harsh conditions like wastewater treatment or abrasive fluid handling.
Additionally, the FPI Mag’s versatility extends to various pipe sizes and materials, making it a highly adaptable solution for diverse applications. With real-time flow data accuracy, ease of use, and significant cost savings, the FPI Mag represents the next generation of flow measurement technology, providing a robust and reliable solution for any flow monitoring needs.
Key Features of the FPI Mag Meters:
- Unmatched Accuracy The FPI Mag® delivers precision that meets or exceeds industry standards, with an accuracy of ±0.5%, as verified by third-party testing. This ensures reliable and consistent flow measurement for critical applications.
- Effortless Installation Designed for convenience, the FPI Mag® features an insertion design that allows for hassle-free hot tap installation. This means you can install the meter without interrupting service, de-watering lines, or performing complex pipe modifications, such as cutting or welding flanges.
- Maintenance-Free Operation With no moving parts, the FPI Mag® is engineered for durability and minimal maintenance. Its multi-electrode sensor design is immune to wear and tear, making it resistant to clogging by sand, grit, or other debris, ensuring long-lasting performance.
- Durable and Robust Construction Built to withstand harsh environments, the FPI Mag® features a sensor body made from high-strength 316 stainless steel. It is hermetically sealed and protected by an NSF-certified 3M fusion-bonded epoxy coating, ensuring maximum structural integrity. The electrodes are made of stainless steel by default, with Hastelloy available as a custom option for enhanced corrosion resistance.
Benefits of the FPI Mag Meter:

- Accuracy: When it comes to accuracy, magnetic flow meters are highly accurate, which means they meet or exceed exacting industry standards of ±0.5% accuracy.
- Profile: The FPI Mag captures the complete profile compared to other meters.
- Installation: Simple installation means hot tab, attaching installation fittings, and inserting the meter. That’s it—you’re done.
- Tight space: Applications where it’s impossible to deploy a full-bore meter, FPI makes installation easy in small, tight vaults, pip work in ceiling or any basement areas.
Applications where FPI wins over other meters:
- Line Size: When it comes to line size, FPI from McCrometer’ is capable of 4 to 138″ (100 mm to 3,500 mm). Shutting down a 138″ line to repair it is not a small task. Therefore, FPI makes the best choice and an ideal solution due to its hot tap feature.
- Easy to be placed into and removed from service: When it comes to periodic cleaning and calibration, we know that cleaning the build-up that occurs on a meter’s electrodes ultimately affects performance. It can be frustrating for the full-bore mag, but with FPI Mag, it’s a simple step to extract the meter, clean the sensor, and put it back into service.
- Space Consideration: FPI does wonders even in tight space applications compared to the other meters.
- Water Loss Prevention: FPI is not just a meter, it’s a solution. It has the unique ability to improve operations by identifying and preventing water loss due to leaks, breaks, and other metering or infrastructure failures. This should provide a sense of security and reassurance about the effectiveness of the FPI.
Why is FPI called the Next Generation Mag Meter?
The FPI Magnetic Flow Meter distinguishes itself from traditional insertion meters by capturing the full flow profile across the pipe diameter. This is achieved through a unique multi-electrode array that measures fluid velocity at various points, ensuring a comprehensive and accurate flow measurement.
Its key advantage lies in the hot tap installation, which allows the meter to be inserted and removed without shutting down the pipeline. This feature makes it ideal for large pipelines where interruptions are costly. The FPI also requires minimal maintenance, with no moving parts, ensuring long-term reliability and easy cleaning without downtime.
In short, the FPI Mag Meter provides the accuracy of a full-bore meter, with the installation ease and cost-effectiveness of an insertion meter, making it an optimal solution for large-scale applications.
Certifications & Specs:
Certifications:
• ISO 9001:2015 certified quality management system
• NSF/ANSI/CAN 61
• NSF/ANSI 372
• Certified by MET to UL 61010-1
• Certified by MET C22.2 No. 61010-1-04
• NEC & CEC: Class 1, Division 2, Groups A-D, Groups A-D, T5
• NEC & CEC: Class 2, Zone 2, Groups A-D, T5
| Specification | Details |
| Accuracy | ± 0.5% from 1 ft/s to 32 ft/s (0.3 m/s to 10 m/s) |
| ± 1% from 0.3 ft/s to 1 ft/s (0.1 m/s to 0.3 m/s) | |
| Body Material | 316 Stainless Steel Sensor Body, Insertion Hardware, and Sensor Electrodes |
| NSF Certified 3M Fusion-Bonded Epoxy Coating | |
| Line Size | 4 to 138″ (100 mm to 3,500 mm) |
| Range | 0.3 ft/s – 32 ft/s (0.1 m/s – 10 m/s) |
| Repeatability | 0.3% of reading |
Installation, Calibration & Maintenance for FPI Mag Meters
Click here to download the manual:
Accessories:
The signal converter is the electromagnetic flow meter’s reporting, input, and output control device. It is available as a meter mount or a remote mount.

The converter allows measurements, functional programming, sensor control, and data recording to be communicated through the display and inputs and outputs.
How to choose a Magnetic Flow Meter:
Here are the key aspects for you to consider while choosing a mag meter (magnetic or electromagnetic flow meter):

1. Cost and Accuracy:
- How important is accuracy for your application?
- Higher accuracy means higher cost. Are you willing to pay more for precise measurements, especially for high flow rates or large pipelines?
- Which type of meter suits your needs?
- Full-bore meters offer greater precision, but are insertion meters more cost-effective for your large pipes?
2. Application and Fluid Characteristics:
- Is your fluid conductive?
- Ensure the fluid’s conductivity is above 5 µS/cm for proper function. Does your application require handling lower conductivity levels?
- What’s the nature of your fluid?
- Is it abrasive or does it contain slurry? If so, do you need materials like stainless steel or Hastelloy for durability?
- How will temperature and pressure affect the meter?
- Can the meter handle your fluid’s temperature and pressure conditions, both at minimum and maximum levels?
3. Flow Range and Pipe Size:
- What are the flow rates in your process?
- Choose a meter that accommodates the minimum and maximum flow rates. Does your application have variable flow that requires a high turndown ratio?
- How large is your pipeline?
- For smaller pipelines, full-bore meters work best. Would insertion or FPI meters be a more cost-effective choice for larger pipes?
4. Installation Requirements:
- What’s your project type—retrofit or new installation?
- Are you retrofitting existing pipes, expanding, or starting fresh? This will impact the meter type and cost. For large pipes, are insertion meters the better option due to ease of installation?
- Is ease of installation a priority?
- Does your project benefit from full-profile insertion meters like FPI, which offer hot-tap installation without cutting the pipe or shutting down the flow?
5. Output and Display Options:
- Do you need an integral or remote display?
- Which display option is more suitable for your monitoring setup?
- What output signals are required?
- Do you need an analog output like 4-20 mA or a digital signal to integrate with SCADA or other control systems?
6. Additional Considerations:
- Will the pipe remain full during measurement?
- Mag meters require a full pipe for accurate readings. Can your system maintain this condition?
- Are there any other process factors to consider?
- Are there chemical compatibility issues with the meter’s materials? Will installation be affected by space constraints or difficult access points?
By answering these questions, we hope you can select the most suitable magnetic flow meter for your application, ensuring both accuracy and efficiency.
Applications for FPI Mag Meters:
1. Municipal Water Systems:
- Used in distribution networks, effluent monitoring, pumping stations, and wells, ensuring precise flow measurement.
- Ideal for UV dosing systems, maintaining accuracy in water treatment processes.
2. Wastewater Management:
- Essential for recycling, reclaiming, and tracking effluent, providing reliable data for efficient water reuse and compliance.
3. Industrial Facilities:
- Deployed in cooling water, feed water, and effluent wastewater systems, ensuring accurate measurements even in harsh environments.
The FPI Mag offers a significant advantage over its full-bore counterpart, primarily because it is easy to insert and extract the meter under live conditions. Its accuracy is equal to that of a full-bore mag meter, making it an obvious choice as the” Next Generation Mag Meter.”
FAQs on Insertion Mag Meters & FPI Mag Meters
- What is the straight-run requirement for McCrometer’s FPI Mag Meter?
For the FPI Mag, requirements vary based on obstructions like valves (gate, butterfly, double elbow) and can range from zero straight run required to 7 diameters or more. There is extensive information on straight-run requirements in each mag meter’s IOM, and additional support is offered from McCrometer’s sales and technical support teams.
- What is the life expectancy of McCrometer’s FPI Mag meter?
With proper maintenance, McCrometer meters have been installed in-field for decades. As a standard, we offer 2 -5-year warranties, and offer extended warranties at the time of purchase.
- What is the difference between inline and insertion flow meter?
The key difference between inline and insertion flow meters is how they are installed and measure flow. Inline meters are built directly into the pipeline and measure the entire flow, offering higher accuracy. Insertion meters are inserted through an opening and measure only part of the flow, making them easier to install and more cost-effective but typically less accurate than inline meters.
Other posts you may like: