| Category | Details |
|---|---|
| Accuracy | AC or DC power: ±1% of measured value ±0.006 ft/s (± 0.0018 m/s) Battery power: ±1% of measured value ±0.006 ft/s (± 0.0018 m/s) Reverse Flow: ±1% of measured value ±0.006 ft/s (± 0.0018 m/s) |
| Certifications | Standard model: HL model: |
| Conductivity | 5us/cm |
| Converter | ProComm Go Transmitter – May be either meter mount or remote mount |
| Directional Response | Forward and reverse flow indication and forward, reverse, net totalization are standard with all meters |
| Electrical Connections | Compression gland Seals, Quick-Connect |
| Electrode | Type 316 stainless steel, Hastelloy optional |
| IP Rating | Quick Connect: (NEMA 6P/IP68 with remote converter) Compression gland seals: (NEMA 6P/IP68 with remote converter) |
| Liner | 135 epoxy Ultraliner |
| Line Size: | Wafer: 2” & 3” Flanged: 4” to 48” |
| Material | Carbon steel, stainless steel, epoxy liner |
| Measurement Method | Electromagnetic flow based on Faraday’s Law |
| Options | – DC powered converter (10-35 VDC, 21 W) – Meter mounted converter – Extended warranty – ANSI or AWWA flanges – Special lay lengths, including ISO standard lay lengths – Quick connect cable fittings – Converter sun shield – Battery or battery-solar powered converter |
| Outputs | – Modbus – HART – Smart Output™ (Sensus, Itron 6, Itron 9) – Datalogger – Built-in verification |
| Pressure Rating | 150 PSI maximum working pressure 300 PSI maximum working pressure |
| Repeatability | ±0.05% or ±.0008ft/s (±0.25mm/s), whichever is greater |
| Requirements: | Pipe Run Requirements – 2” & 3” wafer style: 3D upstream / 1D downstream – 4” and larger flanged: 1D upstream / 0D downstream |
| Sensor Cable | Standard: 25’/7.6 m McCrometer supplied submersible cable with each remote mount unit. Optional: Up to 500’/152.4 m, or 25’/7.6 m max for battery powered. Quick Connect: Available in standard cable lengths: Feet: 25, 50, 75, 100, 125, 150, 175, 200, 500 Meters: 7.6, 15.25. 22.5, 30.5, 38.1, 45.75, 53.3, 61, 152.4 Custom cable lengths at additional cost |
| Sensor Immersion Depth: | With standard strain relief cable: 9 m (30 ft.) With optional quick connect cable: 1.8 m (6 ft.) |
| Temperature: | Operating Temperature: -10 to 60°C (14 to 140°F) Storage Temperature: -15 to 60°C (5 to 140° F) |
| Velocity Measurement Range | 0.2 to 32 FPS |
| Warranty | 24 months |