iGAS Safe 100 – Gas Detector

Application

iGasSAFE 100 is an intelligent Multi-Sensor-Transmitter/Controller for the connection of up to 3 sensors of the analog (AS) & digital sensors (DS) series. The iGasSAFE 100 offers 2 local bus slots for DS sensors of different gas types and 3 analog inputs for AS sensors with 4–20 mA signal. The transmitter monitors the measured values and activates the alarm relays if the set alarm thresholds for pre-alarm and main alert are exceeded. In addition, the values are provided for direct connection to the BMS/PLC via an RS-485 interface and also as 4–20 mA output.

Key Benefits

  • • Internal Function Monitoring with integrated hardware watchdog
    • Hardware and software according to SIL compliant development process
    • Modular technology (plug-in and exchangeable)
    • Reverse polarity protected, overload and short-circuit proof
    • 2x local bus connection for digital sensors and 3x analog input (4–20 mA) for AS sensors; max. 3 sensors in total
    • 3 relays with SPDT contacts, potential-free max. 250 V AC, 5 A

 

Specifications
Power Supply :24 V DC ± 20 %, reverse-polarity protected
24 V AC ± 15 % (power limited, see ELECTRICAL CONNECTION)
Power consumption (24 V DC)
• Board
• Per sensor (DS)
• Per sensor (AC)
• Horn / warning light:
Max. 60 mA (1.5 VA), w/o sensor, w/o WAO
Max. 40 mA (1.0 VA)
Max. 75 mA (1.8 VA)
Max. 40 mA (1.0 VA)
Alarm relay (2)250 V AC, 5 A; 30 V DC, 2 A, potential-free, contacts (SPDT)
Fault signal relay (1) configurable as alarm relay250 V AC, 5 A; 30 V DC, 2 A, potential-free, contacts (SPDT)
Transistor output (2) :24 V DC/0,1 A (switching to plus) only at 24 V DC power supply
Digital input (2)Potential-free
Analog input (3)4–20 mA, overload and short-circuit proof, input resistance 130 Ω
Analog output signal (1)Proportional, overload and short-circuit proof, load ≤ 500 Ω 4–20 mA = measuring range 3.3–<4 mA = tolerable under range 2.4–<4 mA = tolerable under range (Pellistor) > 20–21.2 mA = tolerable overrange ≥ 21,2 mA= error overrange ≤ 2,0 mA = fault ≤ 1,0 mA = processor power failure
Output for local bus (2)5 V DC, 250 mA max., overload, short-circuit & reverse-pol. protect
Local bus1-wire / 19200 Baud
Field busRS-485 / 19200 Baud
Tool bus2-wire / 19200 Baud
FunctionTransmission of measured values & alarm stages
Ambient Conditions—
Temperature range -25 °C to +60 °C (-13 °F to 140 °F), observe temp. range of options )
Humidity range15–95 % RH non-condensing
Pressure range 80–120 kPa
Storage temperature range-20 °C to +65 °C (-4 °F to 149 °F)
Storage timeCa. 6 months
Humidity Range20–90 % RH non-condensing
Pressure range80–120 kPa
Housing type C/EPolycarbonate
Flammability classification UL 94 V2
Housing colourSimilar to RAL 7035 (light grey) 
Dimensions housing (W x H x D)
• Housing type C
• Housing type E
130 x 130 x 75 mm (5.12 x 5.12 x 2.95 in.)
130 x 130 x 99 mm (5.12 x 5.12 x 3.90 in.)
Weight Max. 0.6 kg (1.32 lbs) 
Protection class (delivery state)IP65 NEMA 4X
InstallationWall Mounting 
Knockouts for cable entry Standard 6x M20/25
Connection type:
• Local bus (AS sensors)
• Digital input, analog output
• Power supply, relays, field bus
Plug-in connector, 3-pin
Screw-type terminals, 0.25–1.3 mm 
Screw-type terminals, 0.25–2.5 mm
 
DirectivesEMC Directives 2014/30/EU
Low Voltage Directive 2014/35/EU
CE
EN IEC 61010-1:2010
Conformity to:
EN 50271
EN 50270 Type I
EN IEC 61508-1–3
EN 50402
EN IEC 62990-1: Type SM
EN 50104
EN 14624
EN 378
Option:
ANSI/UL 61010-1
LC-Display2 lines, 16 characters each, background highlighted in 2 colours 
OperationMenu driven via 6 pushbuttons
Power consumption 5 V, 60 mA, 0.3 VA 
Temperature range -20 °C to +60 °C (-4 °F to 130 °F)
Colour/modeRed/yellow/green (alarm-fault-operation-service) 
Acoustic Pressure> 85 dB (A) (distance 0.1 m)
Frequency2300 Hz ± 300 Hz 
Protection ClassIP65
Wide Range Input100–240 V AC – 50/60 Hz 
Output Rating Type 55 VA
Output Rating Type 715 VA 
Rechargeable Battery 12 V, 0.8 Ah
Operating Time> 60 min 
Average Expected Service Life of Batteries3 years
Temp Range (UPS)-5 °C to +30°C (23 °F to 86 °F) 
  • Oxygen
  • Flammable Gases
  • Refrigerants and Freons
  • Toxic gases
  • Boiler Area
  • Laboratories
  • Food Plants
  • Commercial spaces
  • Industrial applications
  • Chillers
  • Steel industry
  • Universities
  • Research Labs
DocumentDownload
BrochureDownload
Transmitter ManualDownload
Sensor ManualDownload
Model Codes (Universal)Download
 

Coming Soon!