iGAS Safe 200 – Gas Detector

Application

The iGasSAFE 200 digital gas detector is used in industrial areas such as the oil/gas industry, chemical, biogas plants, the petrochemical industry, power plants, water and wastewater facilities, food facilities, and other industrial facilities. The robust design & long life sensors make it an ideal choice for harsh-environment applications, and it integrates easily with our gas controller or any third-party controllers/PLC using a 4–20 mA, RS-485 / Modbus, and relay output signals.

Key Benefits

  • • Continuous self-monitoring
    • Microprocessor with 12-bit converter resolution
    • Long sensor life
    • High accuracy, linearity, repeatability and stability
    • Alarm and fault signal relay
    • Built-in environmental compensation (pressure, humidity and temperature) with our MPS sensor technology
    • Integrated self-test and fault management
    • Proportional 4–20 mA output and serial interface to the control centre
    • Reverse polarity protection, overload protection

Specifications
Power Supply(EX12-1 Series) 20–28 V DC reverse polarity protected.
(EX12-2 Series) 20–28 V DC reverse polarity protected or
24 V AC ± 10 % (21.6–26.4 V AC) ELECTRICAL CONNECTION)

Power consumption 

 

(24 V DC)  3.3 W, 90 mA, max. 130 mA
Control unit Microprocessor with 12-bit converter resolution
Digital filterAveraging in order to increase the EMC immunity
Visual Indications3 LEDs for power, alarm and fault
Analog output signal (active)Proportional, overload and short-circuit proof,
Max. load for UE > 20 V = 350 Ω and UE > 22 V = 500 Ω
4–20 mA = measuring range
3.3–4 mA = tolerable underrange
20–21.2 mA = tolerable overrange
≥ 21.2 mA= error overrange
≤ 2 mA = fault
≤ 1 mA = processor or voltage breakdown
Serial InterfaceSerial data bus
Fault Relay (SPNC)Max. 30 V AC/DC, 1 A
Alarm Relay (SPDT)Max. 30 V AC/DC, 1 A
LCD (optional)2 x 16 characters, 3 status LEDs, 4 menu operating elements
SENSOR ELEMENT 
Measuring PrincipleMPS™
Resolution0.1 % LEL
Accuracy± 2 % LEL
Zero-point variation0.5 % LEL
Temperature range-40 °C to 70 °C (-40 °F to 158 °F)
Humidity range0–100 % RH non-condensing
Pressure range80–120 kPa
Storage temperature range-40 °C to 60 °C (-40 °F to 140 °F)
Life-time15+ years
Calibration15 years
PoisoningPoisoning resistant
MaterialAluminum pressure die-casting, epoxy
coating
ColourRAL 7032 (pebble grey) Natural 
Dimensions housing (W x H x D) Type 1 and 3: 125 x 167 x 83 mm
(4.92 x 6.57 x 3.27 in)
Type 2: 145 x 170 x 107 mm
(5.71 x 6,70 x 4.21 in)
Type Stainless: 145 x 170 x 107 mm

Weight:  Type1, 2, 3

Type Stainless:

Approx. 1.3 kg (2.87 lb) / 1,6 kg (3,53 lb)

Approx. 2.5 kg (5.51 lb)

 

Cable entry: (Type 1, 2, 3)

Type: Stainless

1x, 2x or 3x ¾ in. (Ansi B1.20.1)

2x NPT ¾“ (Ansi B1.20.1)

Protection classHousing protection IP66 to IP68 (depending on the cable glands used) 
MountingWall mounting (sensor head downwards)
Wire connectionSpring-type terminal, 0.08–2.5 mm² (AWG 28–14) 
Temperature
Explosion protection
With display
-40 °C to +60 °C (-40 to 140 °F)
-20 °C to +60 °C (-4 °F to 140 °F)
Pressure range80–120 kPa 
Air velocity< 6 m/s
EU Type Examination Certificate
Electrical Explosion Protection ATEX
BVS 15 ATEX E 129 X
EN IEC 60079-0:2018; EN 60079-1:2014
(DEKRA Testing and Certification GmbH)
 
IECEx Type Examination Certificate
Electrical Explosion Protection
IECEx BVS 16 0038X
IEC 60079-0:2017; IEC 60079-1:2014-06
(DEKRA Testing and Certification GmbH)
Type of Protection(EX12-1 Zone 1) Ex db IIC T4 Gb
-40 °C < Ta < +60 °C
(EX12-2 Zone 2) Ex ec IIC T4 Gc
-40 °C < Ta < +60 °C
 
ATEX Marking

(EX12-1 Zone 1) II 2 G Ex db IIC T4 Gb

(EX12-2 Zone 2) II 3 G Ex ec IIC T4 Gc

EMC TestCertificate PR 18 03 53984 001
EN 50270-2015 Interference immunity & emission: Type 2
(industrial sector)
 

EU Declaration of Conformity

Electrical Explosion Protection

CE_PX2-1_Zone1

CE_PX2-2_Zone2 EN IEC
60079-0:2018 + EN IEC
60079-7:2016 +
A1:2018

Certificates (only housing)  
Housing type 1 and type 3:
FM Certificate of Compl. (3042541)
Housing type stainless steel / type 2: FM
Certif. of Conf. (FM18US0036U)
Class 3600, Class 3615, Class 3810, ANSI/NEMA 250. Explosion proof for
Class I, Division 1, Groups A, B, C and D; dust-ignition-proof for Class II, Division
1, Groups E, F and G, Class III, hazardous (classified) locations, indoors and
outdoors (type 4X).
Housing type 1 and type 3:
CSA Certif. of Compl. (2472857)
Housing type stainless steel / type 2:
CSA Certif. of Compl. (1717515)
Class 2258-02 PROCESS CONTROL EQUIPMENT – For Hazardous Loca
tions
Class 4418-02 OUTLET BOXES AND FITTINGS – For Hazardous Locations
Class I, Div. 1, Groups A, B, C and D; Class II, Div. 1, Groups E, F and G,
Class III, Div. 1; Type 4X
 
Compliances of the sensor elementIEC EN 60079-1 / 60079-11
CSA 22.2 60079-1 / 60079-11
FM 3600 / 3610 ANSI/UL 913
JEDEC JS001-2017 EN 55011
IEC EN 61000-4-3 IEC EN
61000-4-8 IEC 60335-2-40
UL/CSA 60335-2-40 ASHRAE
Standard 15
ASHRAE proposed Standard 15.2P
JRA Standard 4068T:2016R
  • Tunnel
  • Food
  • Beverage Dispensing
  • Laboratory
  • Climate
  • Shipping
  • Hydrogen
  • Battery
  • Biogas
  • Agriculture
  • Waste
  • Process
  • Gas storage
DocumentDownload
Datasheet MPS LELDownload
Datasheet Toxic & OxygenDownload
Display FunctionsDownload
ManualDownload
Model CodesDownload
 

Coming Soon!

Scroll to Top

Request a Quote