RAPTORi – Open Channel Radar Flow Meter

Application

The RAPTORi Radar Flow Meter is mainly used for wastewater measurement of open channel in irrigation area, river, municipal, CSO, sewer flow, and industrial plants. The flowmeter adopts high-precision radar sensor to measure water level and flow velocity, and uses to calculate flow, and takes the influence of the environment around into account for correction. The flow measurement data is provided by Modbus protocol RS485 or custom protocol through serial port. The open channel flowmeter is mainly composed of radar current meter and radar water level meter. The working diagram as follows: Built-in imported 24GHz radar flow meter, 26GHz radar liquid level gauge, CW plane microstrip array antenna radar, non-contact detection, the two-in-one product can realize the measurement of flow rate,water level, instantaneous flow and total flow.

Key Benefits

  • Industrial wastewater discharge
  • Sewer flow monitoring
  • Open channel flow
  • River
  • Canal
  • Irrigation
  • Combined overflow sewage
  • Drainage water monitoring

Signal Output:

  • RS485 Modbus or RS-232

Measuring Range:

  • 0.4~40m (Level)

Velocity:

  • 0.01m/s

Accuracy:

  • ±1.5% FS

Velocity Accuracy:

  • ±1.5% FS

Velocity Resolution:

  • 0.01m/s

Level Accuracy:

  • ±1cm

Level Resolution:

  • 1mm

Beam Angle:

  • Velocity of Flow : 14°x 32°, Water level :11°x 11°

Interval:

  • 1-5000min

Radar Frequency:

  • 24.000~24.250GHz

Output:

  • Modbus RTU RS485/232

Flow Direction:

  • Forward Only

Ambient Temperature:

  • -35℃…+70℃ (-31…+158 °F)

Power Supply:

  • 7-28 VDC

Protection Class:

  • IP68

Area Classification:

  • CE General Purpose

Current (12VDC):

  • <280mA in normal operation, and less than 1mA in sleep mode

Signal Output:

  • RS485 Modbus or RS-232

Measuring Range:

  • 0.4~40m

Velocity:

  • 0.01m/s

Accuracy:

  • ±1.5% FS

Velocity Accuracy:

  • ±1.5% FS

Velocity Resolution:

  • 0.01m/s

Level Accuracy:

  • ±1cm

Level Resolution:

  • 1mm

Beam Angle:

  • Velocity of Flow : 14°x 32°, Water level :11°x 11°

Interval:

  • 1-5000min

Radar Frequency:

  • 24.000~24.250GHz

Output:

  • Modbus RTU RS485/232

Flow Direction:

  • Forward Only

Ambient Temperature:

  • -35℃…+70℃ (-31…+158 °F)

Power Supply:

  • 7-28 VDC

Protection Class:

  • IP67

Area Classification:

  • CE General Purpose

Current (12VDC):

  • <280mA in normal operation, and less than 1mA in sleep mode
  • Industrial wastewater discharge
  • Sewer flow monitoring
  • Open channel flow
  • River
  • Canal
  • Irrigation
  • Combined overflow sewage
  • Drainage water monitoring
DocumentDownload
BrochureDownload
ManualDownload
Model CodesDownload

Coming Soon!

Coming Soon!

Scroll to Top

Request a Quote

Tell us a little about your measurement requirements. Our team will get in touch with you.