SPI Mag 5000 – Municipal

Electromagnetic Application

The SPI Mag Insertion Flow Meter provides a highly cost-effective solution for the accurate measurement of liquid flow in closed conduit, pressurized pipe applications. Unlike conventional magnetic meters, the SPI Mag’s cost is independent of pipe size. Velocity and pipe diameter information are utilized by the SPI Mag to determine flow over wide flow ranges with a high degree of accuracy. The SPI Mag reliably measures flow in water and wastewater as well as any type of industrial flow processes involving conductive fluids such as potable water, slurries, sludge, cooling water, and pulp stock.

Key Benefits

  • ✔ Proven electromagnetic technology based on Faraday’s law
  • ✔ Debris shedding, self-cleaning sensor eliminates costly maintenance
  • ✔ Cost is independent of line size
    ✔Easy Hot Tap Installation – no interruption of flow process
Specifications
CategoryDetails
Accuracy:AC or DC power: ±2% of measured value ±0.006 ft/s (±0.0018 m/s) Battery power: ±2% of measured value ±0.006 ft/s (±0.0018 m/s)
Directional Response:Reads 0 when flow is in reverse
Electrical Connections:Compression gland seals for 0.125” to 0.375” dia. round cable
Insertion Tube:1” stainless steel tube – 12” – will profile 4” pipe ID – 24” – will profile 16” pipe ID – 36” – will profile 28” pipe ID2” PVC tube – 18” – will profile a 10” pipe ID – 24” – will profile a 16” pipe ID – 30” – will profile a 22” pipe ID Opt. stainless steel tube. Specify length – 240” max
IP Rating:IP68 submersible sensor
Line size:2 to 240 inches (50 mm to 6,096 mm)
Material:
  • Sensor: Polyurethane exposed to flow
  • 2” sensor mounting: PVC and Stainless Steel exposed to flow. (Stainless Steel Insertion Tube Optional)
  • Compression seal Buna “N” O-Ring seal exposed to flow
Measurement Method:Electromagnetic flow measurement – Volumetric flow in filled flow conduits 2” (50mm) to 240” (6,096 mm) diameter utilizing insertable velocity sensor. 1” meter = 2” to 30” pipe I.D.; 2” meter = 6” to 240” pipe I.D. – Flow indication in English Standard or Metric units – To determine insertion tube length for typical near wall installations, divide the pipe I.D. by 8 and add 18”. – For full profiles, add 18” to the pipe I.D. – Tube assemblies include rods and mounting hardware
Operating Conditions:Pressure/temperature limits – PVC Insertion Tube: Up to 105°F (41°C) at 150 PSI – Stainless Steel Insertion Tube: Up to 160°F (71°C) at 250 PSI (McCrometer recommends the use of Stainless Steel) – Note regarding storage: During freezing conditions and when meter is not in use, sensor must be removed from pipe and stored in dry conditions. NOTE: Damage to the sensor caused by allowing the sensor freeze in the pipe is not covered by the warranty.
Options:
  • Sensor Insertion Tool
  • Additional Sensor Cable up to 200’ (for longer lengths consult factory)
  • Valves
Sensor Cable:Standard: 25’ McCrometer supplied submersible cable with each remote mount unit Optional: Up to 200 feet, or 25 feet max for battery powered
Velocity Measurement Range:+0.3 to +32 ft/s (+0.09 to +10 m/s)
Warranty:24 months
DocumentDownload
BrochureDownload
ManualDownload
 

Coming Soon!

Coming soon!

Coming soon!

Contact Us for more information or a quote on accessories.