| Gas | Measurement Range |
|---|---|
| O2 | (electrochemical) 0 … 25 % |
| O2 | (paramagnetic) 0 … 25 % |
| NO | (NDIR) 0 … 200/4,000 ppm |
| NO2 | (NDIR) 0 … 150/500 ppm |
| SO2 | (NDIR) 0 … 200/4,000 ppm |
| CO2 | (NDIR) 0 … 40 % |
| CO | (NDIR) 0 … 200/10,000 ppm |
| N20 | (NDIR) 0 … 100/500 ppm |
| CH4 | (NDIR) 0 … 500/10,000 ppm |
| C3H8 | (NDIR) 0 … 200/5,000 ppm |
| H2S | Rang(electrochemical) 0 … 2,000/5,000 ppme 11 |
| H2 | (electrochemical) 0 … 1,000/2,000 ppm |
| Details | Specifications |
| Zero Point Deviation | negligible due to automatic zeroing |
| Deviation | less than 0.2% of the measuring range per month |
| Calculated Components | NOx: NO + NO₂, calculated ppm or mg/m³, user-selectable O₂ reference, combustion calculations (efficiency, heat loss) on special request |
| Display | Illuminated 3.5” TFT color display |
| Interfaces | Illuminated keyboard, password-protected operation, 4 analog outputs 4 … 20 mA, galvanically isolated, max. load: 500 Ω, 2 alarm relays, potential-free contacts: 24 Vdc, 5 A, Data storage and data logger on SD card, RS 485 digital interface (Modbus RTU), DIN rail RS 485, to ProfiBus converter or to Ethernet converter |
| Gas Sampling Probe | HD gas sampling probe, heated ceramic filter with backpurge, or gas sampling probe HD-GW, heated glass wool filter, or LD gas sampling probe, unheated with in-situ sintered metal filter, heated or unheated gas sampling line, PTFE DN 4/6 mm |
| Gas Conditioning | Thermo-electric gas cooler (Peltier) with constant 39.2°F (+4 °C) dew point, Teflon particle filter, internal Viton tubing, Monitored and regulated gas sampling pump, Constant gas flow of 13gal/h (50 l/h), Gas inlet pressure: -80 inH2O … +80 inH2O (-200 … +200 mbar) (hPa), Sample gas outlet: atmospheric pressure |
| Housing | Aluminum housing with red textured paint, continuously monitored housing ventilation with alarm, antifreeze heater 200 W (option) |
| Operating Temperature | (41°F … 113°F) or (14°F … 113°F) with heated housing, (+5 … +45 °C) or (-10 … +45 °C) with housing heating |
| Power Supply | Universal: 90 … 240 Vac, 47 … 63 Hz, 90 W (300 W with heating) |
| Protection | IP 54 |
| Dimensions | (H x W x D) 31.48″ x 27.55″ x 11.02″ (700 x 800 x 280 mm), suitable for wall mounting |
| Weight | approx. 55 lbs (25 kg) |
| Document | Download |
|---|---|
| Brochure | Download |
- Breweries
- C3H8
- CEMS
- CH4
- CO
- CO2 Measured
- CxHy
- Double Heat Exchanger MRU
- ECS
- ECS / NDIR
- ECS / PM
- Emission Monitoring Systems
- H2
- H2S
- N2O
- NDIRplus
- NO
- NO2
- NOx
- O2
- Simple
- SO2
- Stainless Steel AISI-304
Coming Soon!
Contact Us for more information or a quote on accessories.