| Category | Details |
|---|---|
| Accuracy | AC or DC power: ±1% of measured value ±0.006 ft/s (± 0.0018 m/s) Battery power: ±1% of measured value ±0.006 ft/s (± 0.0018 m/s) Reverse Flow: ±1% of measured value ±0.006 ft/s (± 0.0018 m/s)IMPORTANT NOTICE REGARDING FLOW METER ACCURACY: The flow meter, the remote cable and the electronics are factory calibrated for accuracy as a single unit. Changing the remote cable length, even with the splice kit, changes the accuracy of the meter and invalidates the calibration. Each Vera Mag 3000, along with its signal transmitter, undergoes a multiple-point wet flow calibration with ±0.15% uncertainty relative to flow. If desired, the tests can be witnessed by the customer. The McCrometer test facilities are traceable to the National Institute of Standards & Technology. |
| Certifications 2: | Standard model: – ISO 9001:2015 certified quality management system – NSF/ANSI/CAN 61 & NSF/ANSI 372 – Certified by MET to UL 61010-1HL model: – ISO 9001:2015 certified quality management system – NSF/ANSI/CAN 61 & NSF/ANSI 372 – Certified to NSF / ANSI Standards* – Certified by MET to UL 61010-1 and MET C22.2 No. 61010-1-04 – – Class I, Division 2, Groups A-D, T5 – – Class I, Zone 2, IIC T5 |
| Conductivity: | 5 µs/cm |
| Converter: | ProComm GO transmitter May be either meter mount or remote mount |
| Directional Response: | Forward and reverse flow indication and forward, reverse, net totalization are standard with all meters |
| Electrical Connections: | Compression gland seals Quick-Connect |
| Electrode: | Type 316 stainless steel, Hastelloy optional |
| IP Rating: | Flow tube quick connect: (NEMA 6P/IP68 with remote transmitter) Flow tube compression gland seals: (NEMA 6P/IP68 with remote transmitter) |
| Liner: | 3M 135 gray epoxy Ultraliner™ (200°F) |
| Line size: | ANSI #150 Flanged 1.5” 2” 2.5” 3” 4 – 24” AWWA Cl D Flanged 4 – 24” ANSI #300 Flanged 2” 3” 4” – 24” |
| Material: | Carbon steel, stainless steel, epoxy liner |
| Measurement Method: | Electromagnetic flow based on Faraday’s law |
| Options: | – DC powered converter (10-35 VDC, 21 W) – Meter mounted converter – Extended warranty – ANSI or AWWA flanges – Special lay lengths, including ISO standard lay lengths – Quick connect cable fittings – Converter sun shield – Battery or battery-solar powered converter |
| Outputs: | – Smart Output™ (Sensus, Itron 6, Itron 9) – Data logger – Passive 4-20mA – Pulse – Modbus |
| Pressure Rating: | ANSI #150 285 PSI maximum working pressure AWWA Cl D 150 PSI maximum working pressure ANSI #300 500 PSI maximum working pressure |
| Repeatability: | ±0.05% or ±.0008ft/s (±0.25mm/s), whichever is greater |
| Requirements: | Pipe Run Requirements 1.5”, 2”, 2.5” & 3” ANSI#150 Flanged style: 0D upstream / 0D downstream |
| Sensor Cable: | Standard: 25’/7.6 m McCrometer supplied submersible cable with each remote mount unit. Optional: Up to 500’/152.4 m, or 25’/7.6 m max for battery powered. Quick Connect: Available in standard cable lengths: Feet: 25, 50, 75, 100, 125, 150, 175, 200, 500 Custom cable lengths at additional cost. |
| Sensor Immersion Depth: | With standard strain relief cable: 9 m (30 ft.) With optional quick connect cable: 1.8 m (6 ft.) |
| Temperature: | Operating Temperature: -10 to 93°C (14 to 200°F) Storage Temperature: -15 to 93°C (5 to 200° F) |
| Velocity Measurement Range: | 0.2 to 32 FPS |
| Warranty: | 5-year full meter warranty, 5-year battery life days |
• Remote distribution main water
• Remote campus chill water
• Remote boiler feed water
• Remote fire water
• Reuse water inside the fence
• Cooling tower applications
Coming soon!
Coming soon!